Export limit exceeded: 17186 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (17186 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-31930 2026-04-15 8.8 High
A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions < V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions < V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions < V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions < V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions < V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions < V2.135), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions < V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger.
CVE-2024-27629 1 Rordenlab 1 Dcm2niix 2026-04-15 7.8 High
An issue in dc2niix before v.1.0.20240202 allows a local attacker to execute arbitrary code via the generated file name is not properly escaped and injected into a system call when certain types of compression are used.
CVE-2025-32033 2026-04-15 7.5 High
The Apollo Router Core is a configurable, high-performance graph router written in Rust to run a federated supergraph that uses Apollo Federation 2. Prior to 1.61.2 and 2.1.1, the operation limits plugin uses unsigned 32-bit integers to track limit counters (e.g. for a query's height). If a counter exceeded the maximum value for this data type (4,294,967,295), it wrapped around to 0, unintentionally allowing queries to bypass configured thresholds. This could occur for large queries if the payload limit were sufficiently increased, but could also occur for small queries with deeply nested and reused named fragments. This has been remediated in apollo-router versions 1.61.2 and 2.1.1.
CVE-2024-28815 1 Mitel 2 Cmg Suite, Inattend 2026-04-15 9.8 Critical
A vulnerability in the BluStar component of Mitel InAttend 2.6 SP4 through 2.7 and CMG 8.5 SP4 through 8.6 could allow access to sensitive information, changes to the system configuration, or execution of arbitrary commands within the context of the system.
CVE-2024-30253 2026-04-15 7.5 High
@solana/web3.js is the Solana JavaScript SDK. Using particular inputs with `@solana/web3.js` will result in memory exhaustion (OOM). If you have a server, client, mobile, or desktop product that accepts untrusted input for use with `@solana/web3.js`, your application/service may crash, resulting in a loss of availability. This vulnerability is fixed in 1.0.1, 1.10.2, 1.11.1, 1.12.1, 1.1.2, 1.13.1, 1.14.1, 1.15.1, 1.16.2, 1.17.1, 1.18.1, 1.19.1, 1.20.3, 1.21.1, 1.22.1, 1.23.1, 1.24.3, 1.25.1, 1.26.1, 1.27.1, 1.28.1, 1.2.8, 1.29.4, 1.30.3, 1.31.1, 1.3.1, 1.32.3, 1.33.1, 1.34.1, 1.35.2, 1.36.1, 1.37.3, 1.38.1, 1.39.2, 1.40.2, 1.41.11, 1.4.1, 1.42.1, 1.43.7, 1.44.4, 1.45.1, 1.46.1, 1.47.5, 1.48.1, 1.49.1, 1.50.2, 1.51.1, 1.5.1, 1.52.1, 1.53.1, 1.54.2, 1.55.1, 1.56.3, 1.57.1, 1.58.1, 1.59.2, 1.60.1, 1.61.2, 1.6.1, 1.62.2, 1.63.2, 1.64.1, 1.65.1, 1.66.6, 1.67.3, 1.68.2, 1.69.1, 1.70.4, 1.71.1, 1.72.1, 1.7.2, 1.73.5, 1.74.1, 1.75.1, 1.76.1, 1.77.4, 1.78.8, 1.79.1, 1.80.1, 1.81.1, 1.8.1, 1.82.1, 1.83.1, 1.84.1, 1.85.1, 1.86.1, 1.87.7, 1.88.1, 1.89.2, 1.90.2, 1.9.2, and 1.91.3.
CVE-2024-34063 2026-04-15 2.5 Low
vodozemac is an implementation of Olm and Megolm in pure Rust. Versions 0.5.0 and 0.5.1 of vodozemac have degraded secret zeroization capabilities, due to changes in third-party cryptographic dependencies (the Dalek crates), which moved secret zeroization capabilities behind a feature flag and defaulted this feature to off. The degraded zeroization capabilities could result in the production of more memory copies of encryption secrets and secrets could linger in memory longer than necessary. This marginally increases the risk of sensitive data exposure. This issue has been addressed in version 0.6.0 and users are advised to upgrade. There are no known workarounds for this vulnerability.
CVE-2025-7213 1 Fnkvision 1 Fnk-gu2 2026-04-15 6.4 Medium
A vulnerability classified as critical has been found in FNKvision FNK-GU2 up to 40.1.7. Affected is an unknown function of the component UART Interface. The manipulation leads to on-chip debug and test interface with improper access control. It is possible to launch the attack on the physical device. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used.
CVE-2025-15013 1 Floooh 1 Sokol 2026-04-15 5.3 Medium
A vulnerability was identified in floooh sokol up to 5d11344150973f15e16d3ec4ee7550a73fb995e0. The impacted element is the function _sg_validate_pipeline_desc in the library sokol_gfx.h. Such manipulation leads to stack-based buffer overflow. The attack must be carried out locally. The exploit is publicly available and might be used. This product utilizes a rolling release system for continuous delivery, and as such, version information for affected or updated releases is not disclosed. The name of the patch is b95c5245ba357967220c9a860c7578a7487937b0. It is best practice to apply a patch to resolve this issue.
CVE-2024-37676 1 Htop 1 Htop 2026-04-15 8.4 High
An issue in htop-dev htop v.2.20 allows a local attacker to cause an out-of-bounds access in the Header_populateFromSettings function.
CVE-2025-36625 1 Tenable 1 Nessus 2026-04-15 4.3 Medium
In Nessus versions prior to 10.8.4, a non-authenticated attacker could alter Nessus logging entries by manipulating http requests to the application.
CVE-2025-36755 1 Cleverdisplay 1 Blueone 2026-04-15 N/A
The CleverDisplay BlueOne hardware player is designed with its USB interfaces physically enclosed and inaccessible under normal operating conditions. Researchers demonstrated that, after cicumventing the device’s protective enclosure, it was possible to connect a USB keyboard and press ESC during boot to access the BIOS setup interface. BIOS settings could be viewed but not modified. This behavior slightly increases the attack surface by exposing internal system information (CWE-1244) once the enclosure is removed, but does not allow integrity or availability compromise under standard or tested configurations.
CVE-2025-3145 1 Mindspore 1 Mindspore 2026-04-15 3.3 Low
A vulnerability, which was classified as problematic, has been found in MindSpore 2.5.0. Affected by this issue is the function mindspore.numpy.fft.rfft2. The manipulation leads to memory corruption. The attack needs to be approached locally. The exploit has been disclosed to the public and may be used.
CVE-2025-3144 1 Mindspore 1 Mindspore 2026-04-15 3.3 Low
A vulnerability classified as problematic was found in MindSpore 2.5.0. Affected by this vulnerability is the function mindspore.numpy.fft.hfftn. The manipulation leads to memory corruption. It is possible to launch the attack on the local host. The exploit has been disclosed to the public and may be used.
CVE-2024-23980 2026-04-15 7.5 High
Improper buffer restrictions in PlatformPfrDxe driver in UEFI firmware for some Intel(R) Server D50FCP Family products may allow a privileged user to enable escalation of privilege via local access.
CVE-2025-61084 1 Mdaemon 1 Email Server 2026-04-15 7.1 High
MDaemon Mail Server 23.5.2 validates SPF, DKIM, and DMARC using the email enclosed in angle brackets (<>) in the From: header of SMTP DATA. An attacker can craft a From: header with multiple invisible Unicode thin spaces to display a spoofed sender while passing validation, allowing email spoofing even when anti-spoofing protections are in place. NOTE: this is disputed by the Supplier because UI spoofing occurs in a client, not in a server such as MDaemon's product or any other server implementation. Also, if a client without its own spoofing protection must be used, the Header Screening feature in MDaemon's product can be employed to mitigate the client-side vulnerability.
CVE-2025-6093 2026-04-15 5.5 Medium
A vulnerability classified as critical was found in uYanki board-stm32f103rc-berial up to 84daed541609cb7b46854cc6672a275d1007e295. This vulnerability affects the function heartrate1_i2c_hal_write of the file 7.Example/hal/i2c/max30100/Manual/demo2/2/heartrate1_hal.c. The manipulation of the argument num leads to stack-based buffer overflow. Continious delivery with rolling releases is used by this product. Therefore, no version details of affected nor updated releases are available.
CVE-2025-12755 1 Ibm 2 Mq Advanced, Mq Operator 2026-04-15 4 Medium
IBM MQ Operator (SC2 v3.2.0–3.8.1, LTS v2.0.0–2.0.29) and IBM‑supplied MQ Advanced container images (across affected SC2, CD, and LTS 9.3.x–9.4.x releases) contain a vulnerability where log messages are not properly neutralized before being written to log files. This flaw could allow an unauthorized user to inject malicious data into MQ log entries, potentially leading to misleading logs, log manipulation, or downstream log‑processing issues.
CVE-2025-6091 2026-04-15 8.8 High
A vulnerability was found in H3C GR-3000AX V100R007L50. It has been classified as critical. Affected is the function UpdateWanParamsMulti/UpdateIpv6Params of the file /routing/goform/aspForm. The manipulation of the argument param leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor confirms the existence of this issue. Because they assess the risk as low, they do not have immediate plans for remediation.
CVE-2025-6090 1 H3c 1 Gr-5400ax 2026-04-15 8.8 High
A vulnerability was found in H3C GR-5400AX V100R009L50 and classified as critical. This issue affects the function UpdateWanparamsMulti/UpdateIpv6params of the file /routing/goform/aspForm. The manipulation of the argument param leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor confirms the existence of this issue. Because they assess the risk as low, they do not have immediate plans for remediation.
CVE-2024-11999 2026-04-15 8.8 High
CWE-1104: Use of Unmaintained Third-Party Components vulnerability exists that could cause complete control of the device when an authenticated user installs malicious code into HMI product.