| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Padding oracle attack vulnerability in Oberon microsystem AG’s ocrypto library in all versions since 3.1.0 and prior to 3.9.2 allows an attacker to recover plaintexts via timing measurements of AES-CBC PKCS#7 decrypt operations. |
| A vulnerability was identified in coze-studio up to 0.2.4. The impacted element is an unknown function of the file backend/domain/plugin/encrypt/aes.go. The manipulation of the argument AuthSecretKey/StateSecretKey/OAuthTokenSecretKey leads to use of hard-coded cryptographic key
. It is possible to initiate the attack remotely. The attack is considered to have high complexity. The exploitability is regarded as difficult. To fix this issue, it is recommended to deploy a patch. The vendor replied to the GitHub issue (translated from simplified Chinese): "For scenarios requiring encryption, we will implement user-defined key management through configuration and optimize the use of encryption tools, such as random salt." |
| hpke-js is a Hybrid Public Key Encryption (HPKE) module built on top of Web Cryptography API. Prior to version 1.7.5, the public SenderContext Seal() API has a race condition which allows for the same AEAD nonce to be re-used for multiple Seal() calls. This can lead to complete loss of Confidentiality and Integrity of the produced messages. This issue has been patched in version 1.7.5. |
| A “Use of a Broken or Risky Cryptographic Algorithm” vulnerability in the SSL/TLS component used in B&R Automation Runtime versions before 6.1 and B&R mapp View versions before 6.1 may be abused by unauthenticated network-based attackers to masquerade as services on impacted devices. |
| A vulnerability has been identified in RUGGEDCOM i800 (All versions), RUGGEDCOM i801 (All versions), RUGGEDCOM i802 (All versions), RUGGEDCOM i803 (All versions), RUGGEDCOM M2100 (All versions), RUGGEDCOM M2200 (All versions), RUGGEDCOM M969 (All versions), RUGGEDCOM RMC30 (All versions), RUGGEDCOM RMC8388 V4.X (All versions), RUGGEDCOM RMC8388 V5.X (All versions < V5.10.0), RUGGEDCOM RP110 (All versions), RUGGEDCOM RS1600 (All versions), RUGGEDCOM RS1600F (All versions), RUGGEDCOM RS1600T (All versions), RUGGEDCOM RS400 (All versions), RUGGEDCOM RS401 (All versions), RUGGEDCOM RS416 (All versions), RUGGEDCOM RS416P (All versions), RUGGEDCOM RS416Pv2 V4.X (All versions), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.10.0), RUGGEDCOM RS416v2 V4.X (All versions), RUGGEDCOM RS416v2 V5.X (All versions < V5.10.0), RUGGEDCOM RS8000 (All versions), RUGGEDCOM RS8000A (All versions), RUGGEDCOM RS8000H (All versions), RUGGEDCOM RS8000T (All versions), RUGGEDCOM RS900 (All versions), RUGGEDCOM RS900 (32M) V4.X (All versions), RUGGEDCOM RS900 (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RS900G (All versions), RUGGEDCOM RS900G (32M) V4.X (All versions), RUGGEDCOM RS900G (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RS900GP (All versions), RUGGEDCOM RS900L (All versions), RUGGEDCOM RS900M-GETS-C01 (All versions), RUGGEDCOM RS900M-GETS-XX (All versions), RUGGEDCOM RS900M-STND-C01 (All versions), RUGGEDCOM RS900M-STND-XX (All versions), RUGGEDCOM RS900W (All versions), RUGGEDCOM RS910 (All versions), RUGGEDCOM RS910L (All versions), RUGGEDCOM RS910W (All versions), RUGGEDCOM RS920L (All versions), RUGGEDCOM RS920W (All versions), RUGGEDCOM RS930L (All versions), RUGGEDCOM RS930W (All versions), RUGGEDCOM RS940G (All versions), RUGGEDCOM RS969 (All versions), RUGGEDCOM RSG2100 (All versions), RUGGEDCOM RSG2100 (32M) V4.X (All versions), RUGGEDCOM RSG2100 (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RSG2100P (All versions), RUGGEDCOM RSG2100P (32M) V4.X (All versions), RUGGEDCOM RSG2100P (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RSG2200 (All versions), RUGGEDCOM RSG2288 V4.X (All versions), RUGGEDCOM RSG2288 V5.X (All versions < V5.10.0), RUGGEDCOM RSG2300 V4.X (All versions), RUGGEDCOM RSG2300 V5.X (All versions < V5.10.0), RUGGEDCOM RSG2300P V4.X (All versions), RUGGEDCOM RSG2300P V5.X (All versions < V5.10.0), RUGGEDCOM RSG2488 V4.X (All versions), RUGGEDCOM RSG2488 V5.X (All versions < V5.10.0), RUGGEDCOM RSG907R (All versions < V5.10.0), RUGGEDCOM RSG908C (All versions < V5.10.0), RUGGEDCOM RSG909R (All versions < V5.10.0), RUGGEDCOM RSG910C (All versions < V5.10.0), RUGGEDCOM RSG920P V4.X (All versions), RUGGEDCOM RSG920P V5.X (All versions < V5.10.0), RUGGEDCOM RSL910 (All versions < V5.10.0), RUGGEDCOM RST2228 (All versions < V5.10.0), RUGGEDCOM RST2228P (All versions < V5.10.0), RUGGEDCOM RST916C (All versions < V5.10.0), RUGGEDCOM RST916P (All versions < V5.10.0). The affected products support insecure cryptographic algorithms. An attacker could leverage these legacy algorithms to achieve a man-in-the-middle attack or impersonate communicating parties. |
| ci solution CI-Out-of-Office Manager through 6.0.0.77 uses a Hard-coded Cryptographic Key. |
| Reusing a nonce, key pair in encryption issue exists in "FreeFrom - the nostr client" App versions prior to 1.3.5 for Android and iOS. If this vulnerability is exploited, the content of direct messages (DMs) between users may be manipulated by a man-in-the-middle attack. |
| Pheonix App is a Python application designed to streamline various tasks, from managing files to playing mini-games. The issue is that the map of encoding/decoding languages are visible in code. The Problem was patched in 0.2.4. |
| The Use of a Hard-coded Cryptographic Key vulnerability in Juniper Networks Juniper Cloud Native Router (JCNR) and containerized routing Protocol Deamon (cRPD) products allows an attacker to perform Person-in-the-Middle (PitM) attacks which results in complete compromise of the container.
Due to hardcoded SSH host keys being present on the container, a PitM attacker can intercept SSH traffic without being detected.
This issue affects Juniper Networks JCNR:
* All versions before 23.4.
This issue affects Juniper Networks cRPD:
* All versions before 23.4R1. |
| A vulnerability was found in Satellite. When running a remote execution job on a host, the host's SSH key is not being checked. When the key changes, the Satellite still connects it because it uses "-o StrictHostKeyChecking=no". This flaw can lead to a man-in-the-middle attack (MITM), denial of service, leaking of secrets the remote execution job contains, or other issues that may arise from the attacker's ability to forge an SSH key. This issue does not directly allow unauthorized remote execution on the Satellite, although it can leak secrets that may lead to it. |
| In illumos illumos-gate 2024-02-15, an error occurs in the elliptic curve point addition algorithm that uses mixed Jacobian-affine coordinates, causing the algorithm to yield a result of POINT_AT_INFINITY when it should not. A man-in-the-middle attacker could use this to interfere with a connection, resulting in an attacked party computing an incorrect shared secret. |
| A vulnerability has been identified in APOGEE PXC Series (BACnet) (All versions), APOGEE PXC Series (P2 Ethernet) (All versions), TALON TC Series (BACnet) (All versions). Affected devices contain a weak encryption mechanism based on a hard-coded key.
This could allow an attacker to guess or decrypt the password from the cyphertext. |
| Due to outdated Hash algorithm, HCL Glovius Cloud could allow attackers to guess the input data using brute-force or dictionary attacks efficiently using modern hardware such as GPUs or ASICs |
| Web installer integrity check used weak hash algorithm. The following products are affected: Acronis Cyber Protect 16 (Windows) before build 39169. |
| itech iLabClient 3.7.1 relies on the hard-coded YngAYdgAE/kKZYu2F2wm6w== key (found in iLabClient.jar) for local users to read or write to the database. |
| free-one-api allows users to access large language model reverse engineering libraries through the standard OpenAI API format. In versions up to and including 1.0.1, MD5 is used to hash passwords before sending them to the backend. MD5 is a cryptographically broken hashing algorithm and is no longer considered secure for password storage or transmission. It is vulnerable to collision attacks and can be easily cracked using modern hardware, exposing user credentials to potential compromise. As of time of publication, a replacement for MD5 has not been committed to the free-one-api GitHub repository. |
| HCL DRYiCE Optibot Reset Station is impacted by insecure encryption of One-Time Passwords (OTPs). This could allow an attacker with access to the database to recover some or all encrypted values. |
| This vulnerability exists in Tapo C500 Wi-Fi camera due to hard-coded RSA private key embedded within the device firmware. An attacker with physical access could exploit this vulnerability to obtain cryptographic private keys which can then be used to perform impersonation, data decryption and man in the middle attacks on the targeted device. |
| Missing cryptographic key commitment in the Amazon S3 Encryption Client for .NET may allow a user with write access to the S3 bucket to introduce a new EDK that decrypts to different plaintext when the encrypted data key is stored in an "instruction file" instead of S3's metadata record.
To mitigate this issue, upgrade Amazon S3 Encryption Client for .NET to version 3.2.0 or later. |
| Missing cryptographic key commitment in the AWS SDK for C++ may allow a user with write access to the S3 bucket to introduce a new EDK that decrypts to different plaintext when the encrypted data key is stored in an "instruction file" instead of S3's metadata record.
To mitigate this issue, upgrade AWS SDK for C++ to version 1.11.712 or later |