Search Results (2098 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-5967 1 Redhat 3 Build Keycloak, Red Hat Single Sign On, Rhosemc 2026-04-15 2.7 Low
A vulnerability was found in Keycloak. The LDAP testing endpoint allows changing the Connection URL  independently without re-entering the currently configured LDAP bind credentials. This flaw allows an attacker with admin access (permission manage-realm) to change the LDAP host URL ("Connection URL") to a machine they control. The Keycloak server will connect to the attacker's host and try to authenticate with the configured credentials, thus leaking them to the attacker. As a consequence, an attacker who has compromised the admin console or compromised a user with sufficient privileges can leak domain credentials and attack the domain.
CVE-2024-55959 2026-04-15 9.1 Critical
Northern.tech Mender Client 4.x before 4.0.5 has Insecure Permissions.
CVE-2024-55957 2026-04-15 7.8 High
In Thermo Fisher Scientific Xcalibur before 4.7 SP1 and Thermo Foundation Instrument Control Software (ICSW) before 3.1 SP10, the driver packages have a local privilege escalation vulnerability due to improper access control permissions on Windows systems.
CVE-2024-55950 2026-04-15 N/A
Tabby (formerly Terminus) is a highly configurable terminal emulator. Prior to 1.0.216, Tabby terminal emulator contains overly permissive entitlements that are unnecessary for its core functionality and plugin system, creating potential security vulnerabilities. The application currently holds powerful permissions including camera, microphone access, and the ability to access personal folders (Downloads, Documents, etc.) through Apple Events, while also maintaining dangerous entitlements that enable code injection. The concerning entitlements are com.apple.security.cs.allow-dyld-environment-variables and com.apple.security.cs.disable-library-validation. Since Tabby's plugins and themes are NodeJS-based without native libraries or frameworks, and no environment variables are used in the codebase, it is recommended to review and remove at least one of the entitlements (com.apple.security.cs.disable-library-validation or com.apple.security.cs.allow-dyld-environment-variables) to prevent DYLD_INSERT_LIBRARIES injection while maintaining full application functionality. This vulnerability is fixed in 1.0.216.
CVE-2024-52946 1 Lemonldap-ng 1 Lemonldap-ng 2026-04-15 8.8 High
An issue was discovered in LemonLDAP::NG before 2.20.1. An Improper Check during session refresh allows an authenticated user to raise their authentication level if the admin configured an "Adaptative authentication rule" with an increment instead of an absolute value.
CVE-2024-51440 2026-04-15 7.8 High
An issue in Nothing Tech Nothing OS v.2.6 allows a local attacker to escalate privileges via the NtBpfService component.
CVE-2024-48823 1 Automatic Systems 1 Maintenance Slimlane 2026-04-15 9.8 Critical
Local file inclusion in Automatic Systems Maintenance SlimLane 29565_d74ecce0c1081d50546db573a499941b10799fb7 allows a remote attacker to escalate privileges via the PassageAutoServer.php page.
CVE-2024-48822 1 Automatic Systems 1 Maintenance Slimlane 2026-04-15 8.8 High
Privilege escalation in Automatic Systems Maintenance SlimLane 29565_d74ecce0c1081d50546db573a499941b10799fb7 allows a remote attacker to escalate privileges via the FtpConfig.php page.
CVE-2024-4763 1 Lenovo 2 Accessories And Display Manager, Display Control Center 2026-04-15 7.8 High
An insecure driver vulnerability was reported in Lenovo Display Control Center (LDCC) and Lenovo Accessories and Display Manager (LADM) that could allow a local attacker to escalate privileges to kernel.
CVE-2024-46975 2026-04-15 7.9 High
Kernel software installed and running inside a Guest VM may exploit memory shared with the GPU Firmware to write data into another Guest's virtualised GPU memory.
CVE-2024-46974 2026-04-15 7.8 High
Software installed and run as a non-privileged user may conduct improper read/write operations on imported/exported DMA buffers.
CVE-2024-46467 2026-04-15 7.8 High
By default, dedicated folders of ZONEPOINT for Windows up to 2024.1 can be accessed by other users to misuse technical files and make them perform tasks with higher privileges. Configuration of ZONEPOINT has to be modified to prevent this vulnerability.
CVE-2024-46466 1 Primx 1 Zonecentral 2026-04-15 7.8 High
By default, dedicated folders of ZONECENTRAL for Windows up to 2024.3 or up to Q.2021.2 (ANSSI qualification submission) can be accessed by other users to misuse technical files and make them perform tasks with higher privileges. Configuration of ZONECENTRAL has to be modified to prevent this vulnerability.
CVE-2024-46464 2026-04-15 7.8 High
In PRIMX ZED Enterprise up to 2024.3, technical files stored in local folders with common user access can be manipulated to render the host computer unavailable or to execute programs with an elevation of privilege.
CVE-2024-46463 2026-04-15 7.8 High
By default, dedicated folders of ORIZON for Windows up to 2024.3 can be accessed by other users to misuse technical files and make them perform tasks with higher privileges. Configuration of ORIZON has to be modified to prevent this vulnerability.
CVE-2024-46462 2026-04-15 7.8 High
By default, dedicated folders of ZEDMAIL for Windows up to 2024.3 can be accessed by other users to misuse technical files and make them perform tasks with higher privileges. Configuration of ZEDMAIL has to be modified to prevent this vulnerability.
CVE-2024-46505 2026-04-15 9.1 Critical
Infoblox BloxOne v2.4 was discovered to contain a business logic flaw due to thick client vulnerabilities.
CVE-2024-43658 2026-04-15 N/A
Patch traversal, External Control of File Name or Path vulnerability in Iocharger Home allows deletion of arbitrary files This issue affects Iocharger firmware for AC model before firmware version 25010801. Likelihood: High, but requires authentication Impact: Critical – The vulnerability can be used to delete any file on the charging station, severely impacting the integrity of the charging station. Furthermore, the vulnerability could be used to delete binaries required for the functioning of the charging station, severely impacting the availability of the charging station. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads compromised of the integrity and availability of the device (VVC:N/VI:H/VA:H), with no effect on subsequent systems (SC:N/SI:N/SA:N). We do not forsee a safety impact (S:N). This attack can be automated (AU:Y).
CVE-2024-4229 2026-04-15 7.8 High
Incorrect Default Permissions vulnerability in Edgecross Basic Software for Windows versions 1.00 and later and Edgecross Basic Software for Developers versions 1.00 and later allows a malicious local attacker to execute an arbitrary malicious code, resulting in information disclosure, tampering with and deletion, or a denial-of-service (DoS) condition, if the product is installed in a folder other than a folder that only users with administrative privilege have permission to modify.
CVE-2024-39286 2026-04-15 3.3 Low
Incorrect execution-assigned permissions in the Linux kernel mode driver for the Intel(R) 800 Series Ethernet Driver before version 1.15.4 may allow an authenticated user to potentially enable information disclosure via local access.