| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Insyde IHISI function 0x49 can restore factory defaults for certain UEFI variables without further authentication by default, which could lead to a possible roll-back attack in certain platforms. This is fixed in: kernel 5.2, version 05.29.19; kernel 5.3, version 05.38.19; kernel 5.4, version 05.46.19; kernel 5.5, version 05.54.19; kernel 5.6, version 05.61.19. |
| A vulnerability in Kaiten version 57.131.12 and earlier allows attackers to bypass the PIN code authentication mechanism. The application requires users to input a 6-digit PIN code sent to their email for authorization after entering their login credentials. However, the request limiting mechanism can be easily bypassed, enabling attackers to perform a brute force attack to guess the correct PIN and gain unauthorized access to the application. |
| An issue in the BYD Dilink Headunit System v3.0 to v4.0 allows attackers to bypass authentication via a bruteforce attack. |
| Missing Authentication - User & System Configuration |
| SAP NetWeaver AS Java allows an unauthenticated attacker to brute force the login functionality in order to identify the legitimate user IDs. This has an impact on confidentiality but not on integrity or availability. |
| The affected product is vulnerable to an attacker being able to use commands without providing a password which may allow an attacker to leak information. |
| Glutton V1 service endpoints were exposed without any authentication on Gotham stacks, this could have allowed users that did not have any permission to hit glutton backend directly and read/update/delete data. The affected service has been patched and automatically deployed to all Apollo-managed Gotham Instances |
| An issue in Quectel BG96 BG96MAR02A08M1G allows attackers to bypass authentication via a crafted NAS message. NOTE: this is disputed by the supplier. |
| The application is vulnerable to an unauthenticated parameter
manipulation that allows an attacker to set the credentials to blank
giving her access to the admin panel. Also vulnerable to account
takeover and arbitrary password change. |
| An unauthenticated attacker with access to the local network of the
medical office can query an unprotected Fast Healthcare Interoperability
Resources (FHIR) API to get access to sensitive electronic health
records (EHR). |
| A vulnerability has been identified in SiPass integrated AC5102 (ACC-G2) (All versions < V6.4.8), SiPass integrated ACC-AP (All versions < V6.4.8). Affected devices expose several MQTT URLs without authentication. This could allow an unauthenticated remote attacker to access sensitive data. |
| Due to improper BLE security configurations on the device's GATT server, an adjacent unauthenticated attacker can read and write device control commands through the mobile app service wich could render the device unusable. |
| Missing Authentication for Critical Function vulnerability in the mobile monitoring feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric AnalytiX versions 10.97.2 and prior, Mitsubishi Electric MobileHMI versions 10.97.2 and prior, Mitsubishi Electric IoTWorX version 10.95, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.2 and prior, and Mitsubishi Electric Iconics Digital Solutions IoTWorX version 10.95 allows a remote unauthenticated attacker to bypass proper authentication and log in to the system when all of the following conditions are met: (1) Active Directory is used in the security setting (2) "Automatic log in" option is enabled in the security setting (3) The IcoAnyGlass IIS Application Pool is running under an Active Directory Domain Account. (4) The IcoAnyGlass IIS Application Pool account is included in GENESIS64, ICONCIS Suite, and MC Works64 Security and has permission to log in. |
| Siklu MultiHaul TG series devices before version 2.0.0 contain an unauthenticated vulnerability that allows remote attackers to retrieve randomly generated credentials via a network request. Attackers can send a specific hex-encoded command to port 12777 to obtain username and password, enabling direct SSH access to the device. |
| CWE-306: Missing Authentication for Critical Function vulnerability exists that could
cause exposure of private data when an already generated “logcaptures” archive is accessed
directly by HTTPS. |
| The MinigameCenter module has insufficient restrictions on loading URLs, which may lead to some information leakage. |
| There is no limit on the number of failed login attempts permitted with the Clinician Password or the Serial Number Clinician Password. An attacker could execute a brute-force attack to gain unauthorized access to the ventilator, and then make changes to device settings that could disrupt the function of the device and/or result in unauthorized information disclosure. |
| A vulnerability exists in NSD570 login panel that does not restrict excessive authentication attempts. If exploited, this could
cause account takeover and unauthorized access to the system
when an attacker conducts brute-force attacks against the
equipment login. Note that the system supports only one concurrent session and implements a delay of more than a second
between failed login attempts making it difficult to automate the
attacks. |
| In WS_FTP Server versions before 8.8.9 (2022.0.9), an Incorrect Implementation of Authentication Algorithm in the Web Transfer Module allows users to skip the second-factor verification and log in with username and password only. |
| The MinigameCenter module has insufficient restrictions on loading URLs, which may lead to some information leakage. |